工業安全 |
DIERS 緊急釋壓系統-設計實例 |
|
|
|
|
|
|
|
維美通訊曾介紹 DIERS
(Design Institute for Emergency Relief Systems)
功能,特舉一實例以說明如何實際運用。 |
|
|
◎ |
設計緊急釋壓閥之大小(the
required area for the relief valve) - 讓您的製程更安全! |
|
|
|
|
|
主要設計規範: |
 |
|
|
釋壓閥設計壓力: 100
psig |
|
|
Overpressure (%): 20 % |
|
|
液位 : 95% of inside
diameter |
|
|
排放模式= HEM |
(Homogeneous Equilibrium Model) |
|
|
容器模式= Churn
turbulent model |
|
|
火災模式= OSHA 1910.106 |
|
|
|
|
|
|
|
Calculated nozzle area |
: 0.148386 ft2 |
|
Selected valve type |
: 8T10 |
|
Nearest actual nozzle area |
: 0.180556 ft2 |
|
|
|
The following
calculation is base on vent area 0.180556 ft2. |
|
|
|
Calculated vent rate (lb/h) |
= 9.6535e+005 |
|
Calc critical press (psia) |
= 105.6 |
|
Nozzle inlet vapor mass fraction |
= 0.0255067 |
|
Device inlet density (lb/ft3) |
= 28.363 |
|
Nozzle inlet vapor vol. fraction |
= 0.473835 |
|
|
|
以上為部份重要結果,對詳細之細節有興趣者請洽本公司 |
|
|